Brain Computer Interfaces and Neuroprosthetic Control
Unparalleled Performance
Designed for unmatched performance in the most challenging environments, Grapevine Processors & Front Ends provide flexible control and pristine data integrity for BCI and Neuroprosthetic applications. Our novel solutions minimize motion artifacts & electromagnetic interference by amplifying and digitizing neural signals at the electrode resulting in unparalleled data quality.
Take full control over recordings, data processing, trigger output, and stimulation in real-time with our extensive MATLAB and Python APIs. Our Analog and Digital I/O modules provide customizable experimental control.
If you require a mobile platform, look no further. The Trek system supports on-board processing and wireless transmission of data, with an optional external battery increasing total wireless time to up to 8 hours.
Quest HD
Turn-Key Mobile EEG and ERP
Small and lightweight, the Quest HD frees your subjects to move freely and engage in natural behavior. Capable of true high density recording with a max channel count of up to 512 channels, with 24-bit resolution and sampling rate of 7.k ksps for the highest quality data.
Integrating with the Explorer line’s Compass software allows for turn-key setup with automatic device and accessory recognition, and an array of useful features including real-time impedance measurement, integrated video tracking through multiple USB cameras, and graphical control of ERP triggers and configuration.
The Quest HD elimates the need for cables, featuring wireless data transmission, an integrated battery, and internal data storage. With on-board processing, and a bevy of inputs and outputs, and a powerful yet user-friendly API, the Quest HD can be custom programmed for your unique paradigms with real-time control of external devices, stimulators and trackers. In addition to EEG and ERPs, the Quest is also compatible with the Explorer EMG front end for concurrent bipolar EMG recordings.
Highlights
- A completely wearable EEG/ERP solution, with wireless communication and on-board data storage
- On-board processing and an easy-to-use API for custom applications
- Meets safety standards for laboratory and clinical research
Specifications
Quest HD Processor
Number of Channels | up to 512 |
Analog I/O | up to 28 inputs and 28 outputs |
Digital I/O | up to 20 input and 20 outputs, plus 2 strobes |
Battery Life | Internal, up to 2 hours; External, 4 – 6 hours |
Data Communication with PC | Gigabit Ethernet or Wi-Fi |
Dimensions | 183 mm x 95 mm x 36 mm |
Weight | 700 g |
Recording
Resolution | 24-bit |
Inferred Noise | <1 μVrms |
Common Mode Rejection Ratio | -110dB |
Input Range Min | ± 0.1875 V at a gain of 24 |
Input Range Max | ± 2 V at a gain of 1 |
Input Impedance | 1 GΩ, 20 pF |
Quest HD+Stim
Concurrent Transcranial Stimulation and Electroencephalography
Adding to the mobility and features of the Quest HD, the Quest HD+Stim add the ability to do concurrent tCS along with your EEG and ERP recordings.
Powerful on-board processing allows for generation of complex waveforms, allowing you to use common tCS modalities (such as tDCS, tACS, tPCS or tRCS) or experiment with novel waveforms, even modulating or creating stimuli based on the subject’s behavioral or electrophysiological responses. Stimulation can be applied to any of the recording channels, with a switch time of less than a millisecond.
Highlights
- Concurrent tCS and EEG/ERP
- Selectable stimulation channels (switch time < 1ms)
- Closed-loop control of tCS parameters
- All of the mobility and features of the Quest HD
- Meets safety standards for laboratory and clinical research
Specifications
Quest HD Processor
Number of Channels | up to 512 |
Analog I/O | up to 28 inputs and 28 outputs |
Digital I/O | up to 20 input and 20 outputs, plus 2 strobes |
Battery Life | Internal, up to 2 hours; External, 4 – 6 hours |
Data Communication with PC | Gigabit Ethernet or Wi-Fi |
Dimensions | 183 mm x 95 mm x 36 mm |
Weight | 700 g |
Recording
Resolution | 24-bit |
Inferred Noise | <1 μVrms |
Common Mode Rejection Ratio | -115dB |
Input Range Min | ± 0.1875 V at a gain of 24 |
Input Range Max | ± 2 V at a gain of 1 |
Input Impedance | 300 MΩ, 150 pF |
Stimulation
Current Range | 100 μA – 15 mA |
Compliance Voltage | ± 9 V to ± 30 V (configurable) |
Pulse Width Min | 33μs |
Bandwidth | DC to 120kHz |
The EEG family of front ends were designed for noninvasive surface electrodes. As the name implies, it is designed with EEG specifically in mind, however it is suitable for any surface recordings that do not require bipolar or true differential referencing (for these applications the Physio16 is recommended). The stimulation version, the EEG+tES, is designed for stimulation from surface electrodes, such as transcranial stimulation (tCS), or transcutaneous nerve or spinal stimulation (TENS, TSS).
EEG and EEG+tES
Features
- Compatible with any passive EEG cap
- Small, multichannel amplifier combines the signal quality of active caps with the ease-of-use and robustness of passive caps
- Combined with the Quest HD, is ideal for Mobile EEG/ERP
Primary Use Cases
- EEG
- ERP
- tCS
- TENS
- TSS
Specifications
EEG | |
Compatible Processors | Summit or any Quest HD |
Channels | 32 or 128, single reference |
Bit Depth | 24-bit |
Resolution | 0.022 μV/bit |
Sample Rate | 7.5 ksps |
Bandwidth | DC to 2kHz |
CMMR | 110 dB |
Inferred Noise | <1 µVrms at 7.5 ksps |
Input Range Min | ± 0.1875 V at a gain of 24 |
Input Range Max | ± 2 V at a gain of 1 |
Input Impedance | 1 Gohm, 20 pF |
EEG+tES | |
Compatible Processors | Summit or Quest HD+stim |
Channels | 32 or 128, single reference |
Bit Depth | 24-bit |
Resolution | 0.022 μV/bit |
Sample Rate | 7.5 ksps |
Bandwidth | DC to 2kHz |
CMMR | 110 dB |
Inferred Noise | <1 µVrms at 7.5 ksps |
Input Range Min | ± 0.1875 V at a gain of 24 |
Input Range Max | ± 2 V at a gain of 1 |
Input Impedance | 1 Gohm, 20 pF |
Stimulation Waveforms | tDCS, tRNS, tACS, tPCS, user defined |
Stimulation Current Range | ±15 mA |
Compliance Voltage | ±9 to 30V (configurable) |
Min Pulse Width | 33 µs |
Stimulation Frequency | up to 15kHz |
The Explorer line offers two families of front ends for invasive recordings, the Micro2 and the Macro. The Micro2 was designed with high-impedance, micro electrodes in mind. Capable of recording single units, it has a sampling rate of up to 30 ksps. The Micro2+stim is capable of stimulating on all channels simultaneously, making it ideal for all manner of research applications. To avoid delivering excess power to high-impedance electrodes, the Micro2+stim has a lower maximum per channel current compared to the macro
The Macro was designed for standard clinical electrodes. Compared to the Micro2, it has a more focused bandwidth to optimize it for applications such as high-resolution ECoG or sEEG. The Macro2+Stim maximum stimulation current is higher to match common clinical stimulators, while limiting current flow to one anode and one cathode per 16 channel bank to prevent excessive discharge. However, due to the fast switching times common to all Ripple Neuromed stimulating front ends, all channels can be effectively stimulated at once by using interleaved pulse trains.
Macro and Macro+stim Front Ends
Features
- Compatible with macro and microelectrodes
- 1.5mm touchproof connector interface
- Constant current and constant voltage output modes
- One selectable stimulation channel (switch time < 1ms)
- Monopolar or bipolar waveforms
- Programmatic control of waveforms and train parameters
Primary Use Cases
- ECoG
- sEEG
- LFPs
- DBS
- Closed-Loop Stimulation
Specifications
Macro | |
Compatible Processors | Summit |
Channels | 32 or 128, single reference |
Bit Depth | 24-bit |
Resolution | 0.022 μV/bit |
Sample Rate | 7.5 ksps |
Bandwidth | DC to 2kHz |
CMMR | 110 dB |
Inferred Noise | <1 µVrms at 7.5 ksps |
Input Range Min | ± 0.1875 V at a gain of 24 |
Input Range Max | ± 2 V at a gain of 1 |
Input Impedance | 1 Gohm, 20 pF |
Macro+stim | |
Compatible Processors | Summit |
Channels | 32 or 128, single reference |
Bit Depth | 24-bit |
Resolution | 0.022 μV/bit |
Sample Rate | 7.5 ksps |
Bandwidth | 0.03 Hz to 2kHz |
CMMR | 110 dB |
Inferred Noise | <1 µVrms at 7.5 ksps |
Input Range Min | ± 0.1875 V at a gain of 24 |
Input Range Max | ± 2 V at a gain of 1 |
Input Impedance | 1 Gohm, 150 pF |
Stimulation Current Range | ±15 mA |
Compliance Voltage | ±9 to 30V (configurable) |
Min Pulse Width | 33 µs |
Stimulation Frequency | up to 15kHz |
Micro2 and Micro2+stim Front Ends
Features
Features
- High resolution, high sampling rate (30 ksps) recording
- Stimulation on all channels
- Programmatic control of waveforms and train parameters
Primary Use Cases
- Single unit/multi-unit activity
- ECoG
- LFPs
- Closed-Loop Stimulation
Micro2 | |
Compatible Processors | Summit |
Channels | 32, single reference |
Bit Depth | 24-bit |
Resolution | 0.125, 0.25, or 0.5 μV/bit |
Sample Rate | 30 ksps |
Bandwidth | 0.1 Hz to 2 kHz |
CMMR | 82 dB |
Inferred Noise | 2.1 µVrms |
Input Range Min | ± 4 mV |
Input Range Max | ± 12 V |
Micro2+stim | |
Compatible Processors | Summit |
Channels | 32, single reference |
Bit Depth | 24-bit |
Resolution | 0.125, 0.25, or 0.5 μV/bit |
Sample Rate | 30 ksps |
Bandwidth | 1 Hz to 7.5 kHz |
CMMR | 82 dB |
Inferred Noise | 2.1 µVrms |
Input Range Min | ± 4 mV |
Input Range Max | ± 12 mV |
Stimulation Current Range | ±1.5 mA |
Compliance Voltage | ±8.5V |
Min Pulse Width | 33 µs |
Stimulation Frequency | up to 15kHz |
The Physio was designed specifically with electromyography in mind, although can be used for any type of electrophysiology from the body, such as ECG or noninvasive peripheral nerve recordings. It comes in both a 32 channel shared reference version, as well as a 16 channel bipolar version. The Physio does not have a stimulating version, but can be used with stimulating front ends for applications that need stimulation, such as electrically evoked potentials.
Physio 16 and Physio 32 Front Ends
Features
- 16 differential pairs or 32 single-ended channels
- Designed for bipolar EMG or single-ended HD EMG recordings
- 52 mm x 36 mm x 4.75 mm
- 13.5 g
Primary Use Cases
- EMG
- MEP
- Noninvasive Peripheral Nerve recordings
Specifications
Physio16 |
|
Compatible Processors | Summit or any Quest HD |
Channels | 16, true differential referencing |
Bit Depth | 24-bit |
Resolution | 0.022 μV/bit |
Sample Rate | 7.5 ksps |
Bandwidth | DC to 2kHz |
CMMR | 110 dB |
Inferred Noise | <1 µVrms at 7.5 ksps |
Input Range Min | ± 0.1875 V at a gain of 24 |
Input Range Max | ± 2 V at a gain of 1 |
Input Impedance | 1 Gohm, 20 pF |
Physio32 | |
Compatible Processors | Summit or any Quest HD |
Channels | 32, single reference |
Bit Depth | 24-bit |
Resolution | 0.022 μV/bit |
Sample Rate | 7.5 ksps |
Bandwidth | DC to 2kHz |
CMMR | 110 dB |
Inferred Noise | <1 µVrms at 7.5 ksps |
Input Range Min | ± 0.1875 V at a gain of 24 |
Input Range Max | ± 2 V at a gain of 1 |
Input Impedance | 1 Gohm, 20 pF |
The Quest HD and Quest HD + Stim processors are ideally suited for Brain Computer Interface and real time feedback applications. At merely 700 grams, the Quest provides a light weight and portable form factor. A unique active front end, multiple analog and digital inputs and outputs and extremely low latency processing ensure Quest is well suited for your challenging research environments.
Matlab and Python APIs are included with the Quest systems and provide full control over recording, data processing, trigger output and stimulation. Python “code on the box” can be added for the fastest and most streamlined real time data processing. The Quest’s input and output capabilities can be completely utilized by the API ensuring you can utilize the full feature of the Quest for your Brain-Computer Interface applications. Our unique Active Front End design results in unparalleled signal fidelity, a key requirement for many single trial Brain Computer Interface applications.
The Quest HD + Stim adds an entirely new dimension to real time feedback, allowing closed loop feedback control of transcranial electrical stimulation. With custom programed stimulation patterns and intensities, initiated with custom programed data processing the possibilities are endless.
Highlights
- A completely wearable EEG/ERP solution
- Wired, WiFi or self-contained recording
- Optimized real-time data transfer
- Python code runs on the on-board processor
- Matlab and Python APIs for custom applications
- Unique Active Front End designMulti-modal recording and stimulation options
- Up to 56 Analog and 40 Digital IO channels